Home » Material Survey » Sendust
Material survey
Sendust material survey |
|
|
Sendust material |
µ
at 25 ° c
|
Bsat
(mT) at 25 ° c (100 kA/m)
|
Maximum
operating temperature
(° C)
|
Main
application area
|
Available
core shapes
|
Datasheets
 |
|
Sendust 26
|
26
|
» 1000
|
130
|
output choke
|
toroids
|
sendust.pdf |
|
Sendust 60
|
60
|
» 1030
|
130
|
|
Sendust 75
|
75
|
» 1040
|
130
|
|
Sendust 90
|
90
|
» 1050
|
130
|
|
Sendust 125
|
125
|
» 1060
|
130
|
|
 |